Input specifications: 1-channel temperature and humidity input module (built-in) Measurement range: Temperature: -19℃~ 99℃ Humidity: 0%~ 99% RH Basic error: Temperature: +1.5℃ (0℃~ 100℃) Humidity: +5% RH (10%~ 99%) Resolution: Temperature 1℃, Humidity 1%RH Working power: 220VAC, 50/60Hz, default dehumidification power is 15W, please specify if you need other power Recommended dehumidification space: 0.5~1m3 Working power: temperature 0~50℃, humidity ≤85% RH in non-corrosive places Pipe length: high temperat
Request QuoteTechnical Specifications
| Model | HCS-15 |
| Comm. mode | RS485 comm. (Modbus protocol) |
| Resolution | Temp.: 1°C Humidity: 1%RH |
| Basic error | Temp.: +1.5°C(0°C~ 100°C), Humidity: +5% RH(10%~99% ) |
| Input spec. | 1-circuit temperature and humidity input module (built-in) |
| Pipe length | High temperature resistant silicone hose, 1m standard length, please specify for any other size |
| Control mode | Humidity: high humidity control; temperature: low or high temperature control (optional); temperature output: 1-circuit relay output (passive), 250VAC/3A or 30VDC/3A |
| Fault output | One-circuit passive fault output |
| Supply voltage | 20VAC, 50/60Hz, default dehumidification power 15W, please specify for any other power |
| Measuring range | Temp.: -19°C~99°C Humidity: 0%~ 99% RH |
| Work environment | Non-corrosive environment with temperature of 0~50°C and humidity ≤ 85% RH |
| Working condition water output | Default dehumidification power 30W, please specify for any other power |
| Recommended dehumidification space | 0.5~1m³ |